Yangın ve Güvenlik Dergisi 170. Sayı (Ekim 2014)

<$1*,1 YH *h9(1/ø. 6$<, 80 øù *h9(1/øöø 0$.$/( • ISO 16900-1 - Respiratory protective devices. Methods of test and test equipment Part 1: Determination of inward leakage 60.0013.340.30ISO 16900-2:2009. • Respiratory protective devices. Metho- ds of test and test equipment Part 2: Determination of breathing resistance 60.6013.340.30ISO 16900-3:2012. • Respiratory protective devices. Methods of test and test equipment Part 3: De- termination of particle filter penetration 60.6013.340.30ISO 16900-4:2011. • Respiratory protective devices. Met- hods of test and test equipment Part 4: Determination of gas filter capa- city and migration, desorption and carbon monoxide dynamic testing 60.6013.340.30ISO/CD 16900-5. • Respiratory protective devices. Methods of test and test equipment Part 5: Breat- hingmachine/metabolic simulator/RPD headforms/torso, tools and transfer stan- dards 30.6013.340.30ISO/DIS 16900-6. • Respiratory protective devices. Metho- ds of test and test equipment Part 6: • Mechanical resistance/strength of components and connections 40.2013.340.30ISO/DIS 16900-7. • Respiratory protective devices. Metho- ds of test and test equipment Part 7: • Practical performance test methods 40.2013.340.30ISO/DIS 16900-8. • Respiratory protective devices. Met- hods of test and test equipment Part 8: Measurement of RPD air flow rates of assisted filtering RPD 40.6013.340.30ISO/DIS 16900-9.2. • Respiratory protective devices. Met- hods of test and test equipment Part 9: Determination of carbon dioxide content of the inhaled air 40.6013.340.30ISO/DIS 16900-10. • Respiratory protective devices. Metho- ds of test and test equipment Part 10: Resistance to ignition, flame, radiant heat and heat 40.2013.340.30ISO 16900-11:2013. • Respiratory protective devices. Met- hods of test and test equipment Part 11: Determination of field of vision 60.6013.340.30ISO/FDIS 16900-12. • Respiratory protective devices. Methods of test and test equipment Part 12: De- termination of volume-averaged work of breathing and peak respiratory pres- sures 50.2013.340.30ISO/DIS 16900-13. • Respiratory protective devices. Met- hods of test and test equipment Part 13: RPD using regenerated breathable gas and special application mining escape RPD: Consolidated test for gas concentration, temperature, hu- midity, work of breathing, breathing resistance, elastance and duration 40.2013.340.30ISO/DIS 16900-14. • Respiratory protective devices. Met- hods of test and test equipment Part 14: Measurement of sound level 40.2013.340.30ISO 16972:2010. • Respiratory protective devices. • Terms, definitions, graphical sym- bols and units of measurement 60.6013.340.30ISO/DTS 16973. • Respirator y protective devices. Classification 30.9913.340.30ISO/TS 16974:2011. • Respiratory protective devices. Marking and information supplied by the manu- facturer 90.2013.340.30ISO/DIS 16975-1. • Respiratory protective devices. Sele- ction, use and maintenance Part 1: Establishing and implementing a res- piratory protective device programme 40.2013.340.30ISO/DTS 16975-2. • Respiratory protective devices Part 2: Guidance for selection, useandmainte- nance 30.6013.340.30ISO/CD 16975-3. • Respiratory protective devices Part 3: Selection, use and maintenance - Fit testing procedures 30.6013.340.30ISO/ TS 16976-1:2007. • Respiratory protective devices. Human factors Part 1: Metabolic rates and res- piratory flow rates 90.6013.340.30ISO/ TS 16976-2:2010. • Respiratory protective devices. Hu- man factors Part 2: Anthropometrics 90.6013.340.30ISO/TS 16976-2:2010/ Cor 1:2011 and 60.6013.340.30ISO/ TS 16976-3:2011. • Respiratory protective devices. Human factors Part 3: Physiological responses and limitations of oxygen and limitati- ons of carbon dioxide in the breathing environment 60.6013.340.30ISO/TS 16976-4:2012. • Respiratory protective devices. Human factors Part 4: Work of breathing and breathing resistance: Physiologically based limits 60.6013.340.30ISO/TS 16976-5:2013. • Respiratory protective devices. Hu- man factors Part 5: Thermal effects 60.6013.340.30ISO/TS 16976-6:2014. • Respiratory protective devices. Human factors Part 6: Psycho-physiological effe- cts 60.6013.340.30ISO/TS 16976-7:2013. • Respiratory protective devices. Human factors Part 7: Hearing and speech 60.6013.340.30ISO/TS 16976-8:2013. • Respiratory protective devices. Human factors Part 8: Ergonomic factors 60.6013.340.30ISO/CD 17420-1. • Respirator y protective devices. Performance requirements Part 1: Supplied breathable gas devices 30.6013.340.30ISO/CD 17420-2. • Respiratory protective devices. Perfor- mance requirements Part 2: Filtering de- vices 30.6013.340.30ISO17420-3:2012. • Respiratory protective devices. Perfor- mance requirements Part 3: Thread connection 60.6013.340.30 (Endnotes) 1 EHS Today - Herris, 2009. Eri ü im tari- hi02/07/2014: http://ehstoday.com/ppe/ respirators/regulation_innovation_shaped 2 úü çilerin yaralanmalar × n × ve hastalan- malar × n × önlemek amac × yla ara ü t × rma yapan ve öneriler sunan bir ABD Fede- ral ajans × . (http://www.cdc.gov/niosh/ about.html) (ÇN)

RkJQdWJsaXNoZXIy MTcyMTY=